current position:HOME > news > products information >

Maintenance of reducer

时间:2018-10-27 16:21   tags: products information  

        How to maintain the reducer.
XNUMX. Check the oil level
  Cut off the power to prevent electric shock!Wait for the reducer to cool down!
  Remove the oil level plug to check if the oil is full.
  Install the oil level plug.

XNUMX. Oil inspection
  Cut off the power to prevent electric shock!Wait for the reducer to cool down!
  Open the oil drain plug and take an oil sample.
  Check the viscosity index of the oil
  —If the oil is obviously turbid, it is recommended to replace it as soon as possible.
  For reducer with oil level plug
  —Check the oil level, whether it is qualified
       —Install the oil level plug

Three, oil replacement
  After cooling, the viscosity of the oil increases and it is difficult to drain the oil. The reducer should change the oil at the operating temperature.
  Cut off the power to prevent electric shock!Wait for the reducer to cool down and there is no danger of burning!
  Note: The reducer should still be warm when changing the oil.
  Place an oil pan under the oil drain plug.
  The reducer opens the oil level plug, breather and oil drain plug.
  Drain all the oil.
  Install the oil drain plug.
  Inject new oil of the same brand.
  The amount of oil should be consistent with the installation position.
  Check the oil level at the oil level plug.
  Tighten the oil level plug and breather.